Zeiss LSM980: Unterschied zwischen den Versionen
Admin (Diskussion | Beiträge) Die Seite wurde neu angelegt: „= Type of device = Confocal laser scanning microscope by Zeiss = Short description = The Zeiss LSM980 with Airyscan 2 is optimized for the simultaneous spectral detection of multiple weak labels with highest light efficiency. It offers excellent imaging performance combined with low phototoxicity and high speed. It can be used for multi-color experiments with living or fixed samples with highest sensitivity and spectral flexibility. = Instrument param…“ |
Admin (Diskussion | Beiträge) Keine Bearbeitungszusammenfassung |
||
Zeile 9: | Zeile 9: | ||
= Instrument parameters = | = Instrument parameters = | ||
{| border="2" | {| border="2" | ||
|style="width:200px; text-align:left;" |Technical specifications: ||style="width: | |style="width:200px; text-align:left;" |Technical specifications: ||style="width:500px; text-align:left;" | | ||
:Inverse microscope LSM 980 | :Inverse microscope LSM 980 | ||
:Incubator XLmulti S1 with temperature control | :Incubator XLmulti S1 with temperature control | ||
Zeile 48: | Zeile 48: | ||
= Affiliation, Contact & Terms of use = | = Affiliation, Contact & Terms of use = | ||
{| border="2" | {| border="2" | ||
|style="width:200px; text-align:left;" |Affiliation: ||style="width: | |style="width:200px; text-align:left;" |Affiliation: ||style="width:500px; text-align:left;" | | ||
:XXXX | :XXXX | ||
|- | |- |
Version vom 29. April 2025, 12:51 Uhr
Type of device
Confocal laser scanning microscope by Zeiss
Short description
The Zeiss LSM980 with Airyscan 2 is optimized for the simultaneous spectral detection of multiple weak labels with highest light efficiency. It offers excellent imaging performance combined with low phototoxicity and high speed. It can be used for multi-color experiments with living or fixed samples with highest sensitivity and spectral flexibility.
Instrument parameters
Technical specifications: |
|
Objectives: |
|
Laser: |
|
Software: |
|
Methods & Expertise
Tiles, z-stack, time series, bleaching, FRAP
Reference publications
Komaragiri, Y. , Pires, R. H., Spiegler, S, Dau, H. T., Biedenweg, D., Salas, C. O., Hossain, Md. F., Fregin, B., Gross, S., Gellert, M., Lendeckel, U., Lillig, C. & Otto, O. (2024) Reactive oxygen species induce cell stiffening through lysosomal degradation and subsequent intracellular acidosis in myeloid precursor cells. Communications Physics 7:252
Affiliation, Contact & Terms of use
Affiliation: |
|
Location: |
|
Contact person: |
|
Terms of use: |
|
Biosafety level: |
|