Axio Observer.Z1: Unterschied zwischen den Versionen
Admin (Diskussion | Beiträge) Die Seite wurde neu angelegt: „= Type of device = Fluorescence microscope by Zeiss <br />Axio Observer with Incubation Chamber = Short description = Live Cell Imaging / Fluorescence Microscope / Brightfield = Instrument parameters = {| border="2" |style="width:200px; text-align:left;" |Technical specifications: ||style="width:500px; text-align:left;" | :Upright system :Motorized stage :z-stacking :HPX 120 C light source |- |Objectives: || |- |Fluorescence Filter Sets: || :BF,…“ |
Admin (Diskussion | Beiträge) Keine Bearbeitungszusammenfassung |
||
(7 dazwischenliegende Versionen desselben Benutzers werden nicht angezeigt) | |||
Zeile 2: | Zeile 2: | ||
Fluorescence microscope by Zeiss | Fluorescence microscope by Zeiss | ||
<br />Axio Observer with Incubation Chamber | <br />Axio Observer with Incubation Chamber | ||
= Short description = | = Short description = | ||
Zeile 9: | Zeile 10: | ||
= Instrument parameters = | = Instrument parameters = | ||
{| border="2" | {| border="2" | ||
|style="width:200px; text-align:left;" |Technical specifications: ||style="width: | |style="width:200px; text-align:left;" |Technical specifications: ||style="width:700px; text-align:left;" | | ||
:Upright system | :Upright system | ||
:Motorized stage | :Motorized stage | ||
Zeile 15: | Zeile 16: | ||
:HPX 120 C light source | :HPX 120 C light source | ||
|- | |- | ||
| | |Flourescent filter sets: || | ||
:BF, PH1, DICII, DICIII, DAPI, Cy5 (Far Red), GFP, YFP, Texas Red, CFP, Cy7 | :BF, PH1, DICII, DICIII, DAPI, Cy5 (Far Red), GFP, YFP, Texas Red, CFP, Cy7 | ||
|- | |- | ||
|Software: || | |Software: || | ||
:Zen | :Zen 2011 | ||
|} | |||
{| class="wikitable" style="margin:0" | |||
|+ style="text-align:left;" |<span style="font-variant:small-caps">Objectives</span> | |||
|- | |||
! style="width:200px; text-align:left;" |Mag !! style="width:100px; text-align:left;" |NA !! style="width:100px; text-align:left;" |Oil? !! style="width:100px; text-align:left;" |DIC? | |||
|- | |||
| 5x || 0.16 || No || No | |||
|- | |||
| 10x || 0.30 || No || Ph1 | |||
|- | |||
| 20x || 0.8 || No || DICI | |||
|- | |||
|40x || 0.75 || No || DICII | |||
|- | |||
|63x EC Plan-Neofluar || 1.4 || Yes || DICII | |||
|} | |} | ||
{| class="wikitable" style="margin:0" | |||
|+ style="text-align:left;" |<span style="font-variant:small-caps">Fluorescence Filter Sets</span> | |||
|- | |||
! style="width:200px; text-align:left;" |Filterset !! style="width:100px; text-align:left;" |Excitation !! style="width:100px; text-align:left;" |Beamsplitter !!style="width:100px; text-align:left;" | Emission | |||
|- | |||
| 43 HE (DsRed) || 550/25 || 570 || 605/70 | |||
|- | |||
| 38 HE (GFP) || 470/40 || 495 || 525/50 | |||
|- | |||
| 49 DAPI || 359/48 || 395 || 445/50 | |||
|} | |||
Zeile 54: | Zeile 85: | ||
= Affiliation, Contact & Terms of use = | = Affiliation, Contact & Terms of use = | ||
{| border="2" | {| border="2" | ||
|style="width:200px; text-align:left;" |Affiliation: ||style="width: | |style="width:200px; text-align:left;" |Affiliation: ||style="width:700px; text-align:left;" | | ||
:XXXX | :XXXX | ||
|- | |- |
Aktuelle Version vom 6. Mai 2025, 11:01 Uhr
Type of device
Fluorescence microscope by Zeiss
Axio Observer with Incubation Chamber
Short description
Live Cell Imaging / Fluorescence Microscope / Brightfield
Instrument parameters
Technical specifications: |
|
Flourescent filter sets: |
|
Software: |
|
Mag | NA | Oil? | DIC? |
---|---|---|---|
5x | 0.16 | No | No |
10x | 0.30 | No | Ph1 |
20x | 0.8 | No | DICI |
40x | 0.75 | No | DICII |
63x EC Plan-Neofluar | 1.4 | Yes | DICII |
Filterset | Excitation | Beamsplitter | Emission |
---|---|---|---|
43 HE (DsRed) | 550/25 | 570 | 605/70 |
38 HE (GFP) | 470/40 | 495 | 525/50 |
49 DAPI | 359/48 | 395 | 445/50 |
Methods & Expertise
Scratch Assay, Sprout Assay, Tube Formation Assay, fluorescence microscopy, live cell imaging
Reference publications
Heusler M, Einenkel R, Ehrhardt J, Muzzio DO, Zygmunt M. Low Abundance Fusobacterium Nucleatum Supports Early Pregnancy Development - An In Vitro Study. Front Immunol. 2021 Aug 31;12:698045. doi: 10.3389/fimmu.2021.698045. PMID: 34531854; PMCID: PMC8438310.
Light Sci Appl. 2022 Sep 7;11(1):265. doi: 10.1038/s41377-022-00952-z. GANscan: continuous scanning microscopy using deep learning deblurring Michael John Fanous 1 2, Gabriel Popescu 3 4 5 Affiliations Expand PMID: 36071043 PMCID: PMC9452654 DOI: 10.1038/s41377-022-00952-z
J Ophthalmol. 2021 Mar 19:2021:6623794. doi: 10.1155/2021/6623794. eCollection 2021. Histopathological Variability and Concomitant Lesions in Pterygium in a Large Case Series Sabrina Bergeron 1, Hiroaki Ito 1 2, Yves E Dossous 1, Miguel N Burnier Jr 1 3 Affiliations Expand PMID: 33828861 PMCID: PMC8004360 DOI: 10.1155/2021/6623794
Diagn Pathol. 2015 Jul 25:10:119. doi: 10.1186/s13000-015-0343-8. Diagnostic imaging of cervical intraepithelial neoplasia based on hematoxylin and eosin fluorescence Mario R Castellanos 1, Anita Szerszen 2, Stephen Gundry 3, Edyta C Pirog 4, Mitchell Maiman 5, Sritha Rajupet 6, John Paul Gomez 6, Adi Davidov 5, Priya Ranjan Debata 7, Probal Banerjee 7, Jimmie E Fata 8 Affiliations Expand PMID: 26204927 PMCID: PMC4513699 DOI: 10.1186/s13000-015-0343-8
Affiliation, Contact & Terms of use
Affiliation: |
|
Location: |
|
Contact person: |
|
Terms of use: |
|
Biosafety level: |
|